Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Radiol. bras ; 53(5): 314-319, Sept.-Oct. 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1136104

ABSTRACT

Abstract Objective: The present study aims to perform a reproducibility study of the clivus-canal angle (CCA), Welcker's basal angle (WBA), and the distance from the odontoid process to Chamberlain's line (DOCL) on magnetic resonance imaging (MRI). Materials and Methods: Two medical students and two radiologists respectively evaluated 100 and 50 consecutive MRI scans of adult skulls, selected randomly. Each examiner, working independently and blinded to the previous results, performed readings for each patient on two different occasions. Measurements were performed in T1-weighted sequences acquired in the midsagittal plane. The levels of intraobserver reproducibility and interobserver agreement were evaluated by calculating the intraclass correlation coefficients (ICCs) and the corresponding 95% confidence intervals. Results: The mean values obtained by the examiners were 150° for the CCA, 130° for the WBA, and 2.5 mm for the DOCL. The ICC for interobserver agreement was 0.980, 0.935, and 0.967, for the CCA, WBA, and DOCL, respectively, for the students, compared with 0.977, 0.941, and 0.982, respectively, for the radiologists, and 0.980, 0.992, and 0.990, respectively, for all of the examiners together. In the analysis of intraobserver agreement, the ICC ranged from 0.929 to 0.959 for the CCA, from 0.918 to 0.964 for the WBA, and from 0.918 to 0.981 for the DOCL. Conclusion: The measurement of the CCA, WBA, and DOCL appears to show excellent intraobserver reproducibility and interobserver agreement on MRI.


Resumo Objetivo: Realizar um estudo de reprodutibilidade do ângulo clivocanal (ACC), ângulo basal de Welcker (ABW) e distância do odontoide à linha de Chamberlain (DOLC) em ressonância magnética (RM). Materiais e Métodos: Quatro examinadores, dois graduandos de medicina e dois radiologistas, avaliaram, respectivamente, 100 e 50 indivíduos adultos submetidos a RM de crânio, consecutiva e aleatoriamente. Cada um realizou duas leituras para cada paciente em diferentes ocasiões, de forma cega e independente. As análises de concordância intraobservador e interobservador foram realizadas pelo coeficiente de correlação intraclasse (CCI), com intervalo de confiança de 95%. Resultados: As medidas médias, considerando todos os examinadores, foram: ACC = 150°, ABW = 130°, DOLC = 2,5 mm. A análise interobservador entre os estudantes revelou CCI de 0,980, 0,935 e 0,967 para ACC, ABW e DOLC, respectivamente, e para os radiologistas, CCI de 0,977, 0,941 e 0,982, respectivamente. A análise interobservador entre estudantes e radiologistas revelou CCI de 0,980, 0,992 e 0,990, respectivamente. Em relação à análise intraobservador, as medidas do ACC tiveram CCI variando entre 0,929 e 0,959, ABW entre 0,918 e 0,964 e DOLC entre 0,918 e 0,981. Conclusão: ACC, ABW e DOLC obtiveram excelentes reprodutibilidades intraobservador e interobservador na RM.

SELECTION OF CITATIONS
SEARCH DETAIL